MODEL
|
OUTPUT
VOLTAGE
|
MAX.
LOAD
|
MIN.
LOAD
|
RIPPLE &
NOISE
|
VOLTAGE
ACCURACY
|
LINE
REGULATION
|
LOAD
REGULATION
|
EFF(1).
(Typ.)
|
|
CFM40M033
|
3.3V
|
6A
|
0A
|
50mV
|
±1
|
±0.5
|
±1
|
76
|
|
CFM40M050
|
5V
|
6A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
8
|
|
CFM40M090
|
9V
|
4.45A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
84
|
|
CFM40M120
|
12V
|
3.34A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
86
|
|
CFM40M150
|
15V
|
2.67A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
87
|
|
CFM40M240
|
24V
|
1.67A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
88
|
|
CFM40M300
|
30V
|
1.33A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
88
|
|
CFM40M360
|
36V
|
1.11A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
88
|
|
CFM40M480
|
48V
|
0.834A
|
0A
|
1
|
±1
|
±0.5
|
±1
|
88
|
|
Specifications
|
CFM40M Series Derating Curve
|
|
INPUT SPECIFICATIONS:
|
Voltage …....………........…............................................. 90~264Vac
|
Frequency ………………………………………………………..... 47 to 63Hz
|
Inrush Current ……………………......................... 60A max. @240Vac
|
Input Current ……….………………. 100Vac/1A max., 240Vac/0.55A max.
|
Leakage Current …………………………………….….…...…… 100uA max
|
OUTPUT SPECIFICATIONS:
|
Holdup Time …………………………..……………… 10ms typ. @115Vac
|
Short Circuit Protection …………………….…. Hiccup Mode (Auto Recover)
|
Over Voltage Protection …………………..…...… TVS Component to Clamp
|
Temperature Coefficient ……………………................................. ±0.05%/℃
|
GENERAL SPECIFICATIONS:
|
Isolation ……………………..…………………..... Input to output=5,656VDC
|
Operating Temperature .............................. 0℃~ 50℃(see Derating Curve)
|
Storage Temperature ………………..…………....….......…........ -20~85℃℃
|
Humidity .................................................... 93% RH max. Non condensing
|
Cooling ………………………..…………………..... Natural Convection
|
Switching Frequency …………………………………….……. 65KHz Typical
|
MTBF …………… MIL-HDBK-217F, GB, 25℃/115VAC …… 200K hrs min.
|
Altitude ……………………..……………………….………..………… 3000m
|
Dimensions ………………….… 3.00x2.00x0.91 Inches(76.2*50.8*23.1mm)
|
Weight…………………………………………………..…………..… 90g
|
NOTE:
|
SAFETY AND EMC:
|
1. Voltage accuracy is set at full load.
|
Emission and Immunity …………. EN55011 Class B, FCC CFR 47 Part 18
|
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
|
EN60601-1-2 , EN61000-3-2 ,EN61000-3-3
|
Ripple & Noise measuring @20MHz BW.
|
Safety …………………………..…… IEC60601-1, EN60601-1, UL60601-1
|
3. Line regulation is measured from 100Vac to 240Vac with full load.
|
4. Load regulation is measured from 1 to full load.
|
5. Connectors: AC input: JST VHor equivalent
|
DC input: JST VH or equivalent
|