PAH50S~PAH150S
|
PAH200S
|
Output voltage
|
2.5V
|
3.3V
|
5V
|
12V
|
15V
|
24V
|
28V
|
48V
(only PAH150S)
|
12V
|
15V
|
24V
|
28V
|
Output voltage range
|
±1
|
-4
~
+15%
|
-4~+1
|
±2
|
-4~+1
|
(By TRM terminal and external resistor)
|
Input voltage range
|
PAH50S~200S:
|
DC48V Input Type DC36~76V
|
|
line regulation
|
0.2%,within nominal input voltage range at constant load
(2.5V.3.3V output : 10mV)
|
Load regulation
|
0.2%.no load to full load at constant input voltage
(2.5V. 3.3V output : 10mV)
|
Cooling
|
Conduction cooling (Heatsink & airflow has to chosen according to instruction manual )
|
Operating ambient temperature
|
Baseplate temperature
|
: -40~+100°C (output derating is different according to condition)
|
|
PAH200S -40°C~+80°C : , +100°C : 9
|
Ambient temperature
|
: above -40°C
|
|
Withstand voltage
|
PAH50S~200S:
|
Input-output / input-baseplate : 1.5kVAC for 1min
Output-baseplate 500VDC : for 1min
|
|
Safty standard
|
PAH50S~200S:
|
Approved UL1950,CSA950 and EN60950
|
|
Fanctions
|
Over voltage protection , Over current protection, Thermal protection, Remote sensing, Remote on / off control
Option : Positive on / off logic , Auto reset Over voltage protection
|