Input
|
|
Input Voltage
|
115 or 230 VAC, 410 Hz +/- 2 are standard (other inputs available upon request)
|
Input Protection
|
Internal safety fuse
Inrush current limiting
Varistor
Lower voltage than specifed minimum input will not damage unit
|
Isolation
|
2250 Vdc input to ground
2250 Vdc input to output
2250 Vdc output to chassis
|
Standards
|
Designed to meet EN60950-1 and related standards
|
EMI
|
EN 55022 Class A as a minimum
|
Output
|
|
Output Voltage
|
115V / 60Hz / 2.2A or 115V / 400Hz / 2.2A or
230V / 50Hz / 1.1A continuous with grounded neutral
Isolated ?oating output optional
|
Output Wave Form
|
Sinusoidal
|
Total Harmonic Distortion
|
Less than 5% at full load
|
Line/Load Regulation
|
± 2% from no load to full load
|
Load Crest Factor
|
Maximum 3.0 at 9 load
|
Output Noise
|
High frequency ripple is less than 500mV rms (20MHz BW)
|
Output Overload Protection
|
Current limiting with short circuit protection. At approximately 300VA unit enter cycling (hiccup)
mode. Thermal shutdown with automatic recovery in case of insuffcient cooling
|
Output Overvoltage Protection
|
140Vac by internal supply voltage limiting
|
Effciency
|
Min 8 at full load
|
Environmental Specifcations
|
|
Operating Temperature Range
|
0°C to +50°C
|
Temperature Drift
|
0.05% per °C over operating temperature range
|
Cooling
|
Conduction/convection
|
Environmental Protection
|
Basic ruggedizing, Conformal coating
|
Shock/Vibration
|
IEC 61373 Cat 1 A&B
|
Humidity
|
5 - 95% non-condensing
|
MTBF
|
110,000 hours @ 45°C
|
Indicators
|
output ON LED
|
Control Input
|
None
|
Alarm Output
|
None
|
Mechanical Specifcations
|
|
Package / Dimensions (W x H x L)
|
F3: 132 x 64 x 300mm (5.2" x 2.5" x 11.8"). Mounting holes are clear
|
Weight
|
2kg (4.4lbs)
|
Connections
|
12-pole barrier-type terminal block,3/8” spacing. Snap-on cover included.
|
Warranty
|
3 years
|